Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1737, Submission # Submission-2019-1821, UID # 21703
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 06/10/2019 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Tank Integrity (Compliance Component #2) - Failing to protect groundwater Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home Excessive ponding in soil system/D-boxes Homeowner testimony (See Comments/Explanation) Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | The drain field distribution box is made of wood. The wood has deteriorated and now is considered a cesspool due to the box no longer being watertight. |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
Yes |
Sewage tank(s) leak below their designed operating depth: |
Yes |
Verification method(s): | Probed tank(s) bottom Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Although not a compliance criteria, it should be noted that the past performance of fiberglass tanks from this era has been substantially unreliable and often leak at the joint between the bottom and top half of the tank. Since it is not feasible to excavate the entire tank, it is impossible for me to guarantee the future performance of the tank or that the tank will not be found watertight in the future. Additionally, the septic tank outlet baffle is missing. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
Explain: | See Report |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Explain: | See Report |
Date of Install
Date of install known: | Yes |
Date of installation: | 01/01/1973 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) Other (See Comments/Explanation) |
Comments/Explanation: | See Report |
A. Bottom of distribution media: | 4.16 Decimal Feet |
B. Periodically saturated soil/bedrock: | 3.33 Decimal Feet |
C. System separation: | 0.8 Decimal Feet |
D. Required compliance separation: | 2 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | See Report |
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | brian@midwestsoiltesting.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #4458 (06/11/2019)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 06/17/2019 2:55 PM $41 Flat Fee |
$41.00 | x 1 | $41.00 |
Grand Total | |||
Total | $41.00 | ||
Payment 06/17/2019 | $41.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Brian Humpal - 06/17/2019 2:55 PM c499d906e38d5f18ec2d4b3232c4586e ab5c93455351e84add4d85e0149397df | |
#1 Compliance Inspection Accepted | Barbara Pena - 06/30/2019 10:13 PM bdd6954204527d2f5236779b4b054df1 6360dba81c9b21fdf5689bb0a4fef90b |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Failed System, Notice and Order to Comply, Separation | Who's signature should be on the letter? | Barbara Pena | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |