Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1912, Submission # Submission-2019-1992, UID # 23787
Status: Compliance Inspection Accepted
 

System Status

System status on date: 09/13/2019 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
0502820210003210 INDIAN TRL S, CITY OF AFTON210INDIANTRLSAFTONCITY OF AFTON55001MORIN JEFFREY R & JILL M11AFTON RIDGE1989
Owner's representative:
Name:
Ryan Edward Lashinski
Phone:
(612919 - 3704
Email:
rlashinski@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Homeowner testimony (See Comments/Explanation)

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Two previous verifications (Attach boring logs)
A. Bottom of distribution media: 3.5 Decimal Feet
B. Periodically saturated soil/bedrock: 6.5 Decimal Feet
C. System separation: 3 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Lashinski SepticL65763-434-39151244 Crosstown Blvd NE Ham Lake, MN 55304YesYesYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: rlashinski@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #4845 (09/13/2019)

Charge Cost Quantity Total
Non-Taxable
added 09/13/2019 5:25 AM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 09/13/2019$41.00
Due$0.00

Approvals

ApprovalSignature
ApplicantRyan E. Lashinski - 09/13/2019 5:26 AM
870a02250c49cb8e5be67b1121608f82
d7d79b9719dcf523637644a83c323867
#1 Compliance Inspection AcceptedDenise Lange - 09/17/2019 1:34 PM
947eb0b336de45de96c59c378b417781
78fdc45141f0688885abb24149afddf3
Inspection has been approved. All signatures have been obtained.