Compliance Inspection Compliance Inspection Compliance Inspection # CI-2020-2047, Submission # Submission-2019-2024, UID # 24116
Status: Compliance Inspection Accepted
 

System Status

System status on date: 09/22/2019 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
270292032000915185 15TH ST N, TOWN OF WEST LAKELAND1518515THSTNSTILLWATERTOWN OF WEST LAKELAND55082XIONG VANG & YENG YANG33ST CROIX VISTA2001
Owner's representative:
Name:
KenHatfield
Phone:
(612387 - 4284
Email:
noemail@noemail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Homeowner testimony (See Comments/Explanation)

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined construction records
Comments/Explanation:
Consulted As-built/construction data from LGU files

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 09/27/2001

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 98.5 Decimal Feet
B. Periodically saturated soil/bedrock: 95.5 Decimal Feet
C. System separation: 36 Decimal Feet
D. Required compliance separation: 36 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
2 X 1000 Gal Septic, 1000gal Pump (Tanks), Five drop boxes X/1 trench w/12" rock below pipe-per box
Consulted A-built/construction data from LGU files
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Advanced Onsite, Inc.L2656952-461-2356313 Lyndale Ave N New Prague, MN 56071NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: aos@bevcomm.net

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #4900 (09/27/2019)

Charge Cost Quantity Total
Non-Taxable
added 09/27/2019 3:08 PM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 01/22/2020$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Klanchnik - 01/22/2020 1:10 PM - witnessed by Denise Lange
11273d65b08bae6891a28e187c02f79d
208d406d5ec68d6dd39e39018f7e26d7
 
#1 Compliance Inspection AcceptedDenise Lange - 01/22/2020 1:28 PM
b553e2170ba25ba2773e2cfbf6da1d6b
46161c91774062535cf60b55aa4c4368
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    Invoiced 12.9.19
    File(s):
    Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
    Was the letter sent? Compliant/Non-Compliant:
    Certificate of Compliance:
      Letter of Non-Compliance:
        Powered by