Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1943, Submission # Submission-2019-2026, UID # 24146
Status: Compliance Inspection Accepted
Status: Compliance Inspection Accepted
System Status
System status on date: | 09/20/2019 | System Status: | Compliant |
Property Information
Property Information: | |||||||||||||||||
Property Owner's Mailing Address (if different than property address): |
|
||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home Homeowner testimony (See Comments/Explanation) |
Comments/Explanation: | Septic tank does not have baffles in place. While the tank is water tight and meets compliance criteria baffles should be added (especially outlet baffle) or the tank replaced to ensure solids are not going to the pump tank and being pumped out to the soil treatment area and reducing the life of the system. |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Probed tank(s) bottom Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Dropped underwater camera into tanks and observed no cracks in either pump tank or septic tank and the liquid level at the outlet invert of the septic tank (see attached picture). No baffles are on the septic tank and this should be remedied, although it is not a compliance criteria |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Explain: | meets required separation. |
Date of Install
Date of install known: | Yes |
Date of installation: | 06/01/1989 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | Yes |
Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock: |
Yes |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | System has 3.27 feet of separation from bottom of media to restriction. |
A. Bottom of distribution media: | 97.36 Decimal Feet |
B. Periodically saturated soil/bedrock: | 94.09 Decimal Feet |
C. System separation: | 3.27 Decimal Feet |
D. Required compliance separation: | 3 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | alex.pepin@tenthirtyenvironmental.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #4903 (09/30/2019)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 09/30/2019 9:20 AM $41 Flat Fee |
$41.00 | x 1 | $41.00 |
Grand Total | |||
Total | $41.00 | ||
Payment 09/30/2019 | $41.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Alex Pepin - 09/30/2019 9:20 AM af8977e8fb91f4bebcdc0765b2acaf96 6632ff747043619cc4843ef1afa059c1 | |
#1 Compliance Inspection Accepted | Kati Hallermann - 10/14/2019 7:31 AM f36697a2e907baffe2bf35338b17027a 68d0ebca9b550c0e541b9a18c5d24e8b |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Who's signature should be on the letter? | Permit number to reference in "No Replace" letter: | |||
Was the letter sent? | Compliant/Non-Compliant: |