Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1973, Submission # Submission-2019-2064, UID # 24534
Status: Compliance Inspection Accepted
 

System Status

System status on date: 10/15/2019 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
31028214300076728 ORCHARD RIDGE TRL, CITY OF WOODBURY6728ORCHARD RIDGETRLWOODBURYCITY OF WOODBURY55129GALVIN JENNIFER72ORCHARD RIDGE ESTATES1998
Property Owner's Mailing Address
(if different than property address):
6728 orchard ridge trl.
woodbury mn 55129
Owner's representative:
Name:
Bob Freiermuth
Phone:
(651437 - 5566
Email:
bfsbob1@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined Tank Integrity Form (Attach)
Examined empty (pumped) tank(s)

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
1-20" top soil 10yr 4/6 , 20-30" 10yr 4/6 sandy loam, 30-40" 10yr 6/6 med to course sand,36-70" 10yr 6/4 course sand , end of bore
A. Bottom of distribution media: .28 Decimal Feet
B. Periodically saturated soil/bedrock: .7 Decimal Feet
C. System separation: .42 Decimal Feet
D. Required compliance separation: .36 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Bob Freiermuth Sanitation LLCL492651-437-556623620 Lillehei Ave Hampton, MN 55031YesYesNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: bfsbob1@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #4988 (10/20/2019)

Charge Cost Quantity Total
Non-Taxable
added 10/20/2019 11:53 AM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 10/20/2019$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBob Freiermuth - 10/20/2019 11:53 AM
341c9ab0f3785c54aff9fb51aad38708
f39e6ea58a5011e78dd6847aeba59c52
 
#1 Compliance Inspection AcceptedDenise Lange - 10/29/2019 12:30 PM
b896a9e50d83e7be5ec4510cd520826b
842936a3279ed50499dc57019a0a2e61
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by