Compliance Inspection Compliance Inspection Submission # Submission-2020-2240, UID # 27421
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 04/15/2020 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Other Compliance Conditions (Compliance Component #3) - Imminent threat to public health and safety Tank Integrity (Compliance Component #2) - Failing to protect groundwater Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
Yes |
Verification method(s): | Probed tank(s) bottom Examined construction records Observed liquid level below operating depth |
Comments/Explanation: | The liquid level is below the operating depth. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
Yes |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
Explain: | The manhole cover is damaged and does not fit properly. |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | Yes |
Date of installation: | 12/16/1975 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | Yes |
Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
A. Bottom of distribution media: | 2.7 Decimal Feet |
B. Periodically saturated soil/bedrock: | 3.1 Decimal Feet |
C. System separation: | .4 Decimal Feet |
D. Required compliance separation: | 3 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | tomtrooien@aol.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #5419 (04/15/2020)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 04/15/2020 2:21 PM $41 Flat Fee |
$41.00 | x 1 | $41.00 |
Grand Total | |||
Total | $41.00 | ||
Payment 04/15/2020 | $41.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Tom Trooien - 04/15/2020 2:21 PM c212c3cd962d25534299afebb363b323 3a571853e3f81ae59d1ba6204c71c913 | |
#1 Compliance Inspection Accepted |
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Imminent Threat, Abatement Notice and Order | Who's signature should be on the letter? | Joe Sanders | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |
|