Compliance Inspection Compliance Inspection Compliance Inspection # CI-2016-0179, Submission # Submission-2016-0212, UID # 2862
Status: Compliance Inspection Accepted
 

System Status

System status on date: 05/17/2016 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
110282043000716544 18TH ST S, CITY OF LAKE ST CROIX BEACH1654418THSTSLAKELANDCITY OF LAKE ST CROIX BEACH55043BENSON KEVIN & CRYSTAL1977
Property Owner's Mailing Address
(if different than property address):
Margaret & Laine Lonergan
17650 200th St E
Hastings Mn 55033
Owner's representative:
Name:
Tom Trooien
Phone:
(612594 - 4496
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes
Homeowner testimony (See Comments/Explanation)

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined construction records

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 08/24/1977

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
B1
0-12 loam topsoil...10yr 3/2
12-29 med to fine sand.....10yr 5/4
29-76 med sand..... 10yr 4/6
A. Bottom of distribution media: 42 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 24 Decimal Feet
D. Required compliance separation: 24 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
1,000 gallon septic tank & 4 lines of gravity drainfield
Attach Files:

Certification

Inspector:
Name:
Tom Trooien
MPCA License #:
L1568
Business Name:
All State
Phone:
(651439 - 7323
Email:
tomtrooien@aol.com
Address:
12020 Square Lake Trail Ct N
Stillwater MN 55082

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #922 (06/03/2016)

Charge Cost Quantity Total
Non-Taxable
added 06/03/2016 10:23 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 06/03/2016$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantLONERGAN MARGARET E & LAINE M MCGEE - 06/06/2016 2:46 PM - witnessed by Kati Hallermann
047128c4dda96144f41f97ca7003a23c
55ed293ef100bf795c21dc8e59582f44
 
#1 Compliance Inspection AcceptedKati Hallermann - 06/06/2016 2:46 PM
257c26e47376ab979df50b194b479e8b
c5d7888c923e60737d8bd96b6c45e330
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by