Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2537, Submission # Submission-2021-2716, UID # 33356
Status: Compliance Inspection Accepted
Status: Compliance Inspection Accepted
System Status
System status on date: | 03/23/2021 | System Status: | Compliant |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Visual Inspection |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Tanks were emptied prior to inspection of tanks. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | Yes |
Date of installation: | 01/28/2005 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Other (See Comments/Explanation) |
Comments/Explanation: | See Soil Boring Lots and Site Plan |
A. Bottom of distribution media: | 91.1 Decimal Feet |
B. Periodically saturated soil/bedrock: | 87.5 Decimal Feet |
C. System separation: | 3.6 Decimal Feet |
D. Required compliance separation: | 3 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | Operating permit and nitrogen BMP questions are Not Applicable |
Attach Files: |
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Contact (If 'self/other' is selected from the Inspector Lookup): | Jesse Kloeppner |
Inspector Email Address: | jesse@ksd-mn.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #6615 (04/13/2021)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 04/13/2021 12:10 PM $42 Flat Fee |
$42.00 | x 1 | $42.00 |
Grand Total | |||
Total | $42.00 | ||
Payment 04/13/2021 | $42.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Jesse J. Kloeppner - 04/13/2021 12:10 PM 9173c6bbfec8609044128213dccfa45a 486fa127c6e982ff18f28888e1f12352 | |
#1 Compliance Inspection Accepted | Tyler Dale - 04/28/2021 2:58 PM 7c3d5c97e0005b625a9c67590c5ac4e7 1eb830bccb7182339466a1607c5e4bdf |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Certificate of Compliance | Who's signature should be on the letter? | Tyler Dale | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Compliant/Non-Compliant: | Compliant |
Certificate of Compliance: |
Letter of Non-Compliance: |