Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2785, Submission # Submission-2021-2988, UID # 35801
Status: Compliance Inspection Accepted
 

System Status

System status on date: 08/20/2021 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
08028202200011243 NEAL AVE S, CITY OF AFTON1243NEALAVESAFTONCITY OF AFTON55001ARNT DAVID & CAROL1880
Owner's representative:
Name:
Dave Arnt
Phone:
(612919 - 4338
Email:
sssepticsolutions@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined empty (pumped) tank(s)

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 10/09/2003

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 2 Decimal Feet
B. Periodically saturated soil/bedrock: 5 Decimal Feet
C. System separation: 3 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
SS Septic Solutions LLCL4137651-343-911714845 113th St S Hastings, MN 55033NoYesNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: sssepticsolutions@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #7254 (08/24/2021)

Charge Cost Quantity Total
Non-Taxable
added 08/24/2021 8:44 PM

$42 Flat Fee

$42.00 x 1 $42.00
Grand Total
Total $42.00
Payment 08/24/2021$42.00
Due$0.00

Approvals

ApprovalSignature
ApplicantShelley L. Schlomka - 08/24/2021 8:44 PM
2ecf567ee3fea2b489db4ec800b686d7
c67e11ed86e992640564fc648ae4e63d
#1 Compliance Inspection AcceptedSarah Borrell - 09/03/2021 12:40 PM
6783a1df9f9bbb3dbc87e49ea862847c
5b896fc39ca84f37ecbb3e343ae2643b
Inspection has been approved. All signatures have been obtained.

Public Notes

Text:
File(s):

    Internal Notes

    Text:
    File(s):
      Powered by