Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-0777, Submission # Submission-2017-0766, UID # 8807
Status: System Replaced
 

System Status

System status on date: 05/15/2017 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Other Compliance Conditions (Compliance Component #3) - Failing to protect groundwater
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
070322022000310311 230TH ST N, CITY OF SCANDIA10311230THSTNSCANDIACITY OF SCANDIA55073NITTI MILINDA LU & BENJAMIN M1970
Owner's representative:
Name:
Larry Christiansen
Phone:
(615333 - 0281
Email:
noemail@noemail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Observed liquid level below operating depth

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
Yes
Explain:
Approx 12" OP soil Seperation

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
see report
A. Bottom of distribution media: 26 Decimal Feet
B. Periodically saturated soil/bedrock: 36 Decimal Feet
C. System separation: 12 Decimal Feet
D. Required compliance separation: 24 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
One septic tank one lift station 5 lines of drainfield drop boxes
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Scandia Compliance Inspections, LLCL3911651-433-330316115 Quality Trl N Scandia, MN 55073NoNoNoNoNo
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Contact (If 'self/other' is selected from the Inspector Lookup): Larry Christiansen
Inspector Email Address: noemail@noemail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #2114 (05/30/2017)

Charge Cost Quantity Total
Non-Taxable
added 05/30/2017 10:38 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 05/30/2017$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantLarry Christiansen - 06/29/2017 9:53 AM - witnessed by Alex Pepin
75640e2230f6bb6896bcdb15352b5d93
353551fea8d45627e275f6f736b1d2b2
 
#1 Compliance Inspection AcceptedAlex Pepin - 06/29/2017 9:54 AM
7d9ed7c7514c4698ac6acd1e044ef623
07f2f3d9d4c57048f3ddb203bb3ddd31
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    Attached soil log and narrative by Pete Ganzel.  
    File(s):
    Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Alex Pepin Permit number to reference in "No Replace" letter:
    Was the letter sent? Yes Compliant/Non-Compliant:
    Certificate of Compliance:
      Letter of Non-Compliance:
        Powered by